Lightning Ridge
Fire & compliance
Independently tested to ASTM E84
Limited contribution to fire, very little smoke and no flaming droplets.
Class A fire rated (ASTM E84): Stick‑A‑Stone and its starter strip in every color; the whole concrete collection — Faux Detroit, Faux New York, Faux Los Angeles, Faux Miami, Faux Columbus, Philly, Faux Travertine and Faux Icelandic Lava; Cotswold Stone and Cottage Lane; Lightning Ridge in Nature's Spirit, Gray Fox, Moonlight Gray and Cappuccino; Earth's Valley and Canyon's Edge in Nature's Spirit and Gray Fox; and the Universal outside corner, Universal ledge trim and outlet covers in those same colors. Harvest Ledge, Traditions, Summit Stone, Aged Brick, British Brick, the faux beams and mantels and the caulking and touch-up kit carry no fire rating claim. Need Class A in a color that isn't listed? Most of our range can be produced in a Class A version to order. There is an upcharge and a lead time - call or text 866-771-2345 and we will quote it.
Class A fire rated (ASTM E84). Surface burning characteristics tested to ASTM E84, the US standard for flame spread and smoke developed. Class A is the top class.
Which products carry it
- Stick-A-Stone and the Stick-A-Stone starter strip, in every color
- The whole concrete range, in every color: Faux Detroit, Faux New York, Faux Los Angeles, Faux Miami, Faux Columbus, Philly, Faux Travertine and Faux Icelandic Lava
- Cotswold Stone and Cottage Lane Faux Brick, in every color
- Lightning Ridge in Nature's Spirit, Gray Fox, Moonlight Gray and Cappuccino
- Earth's Valley and Canyon's Edge in Nature's Spirit and Gray Fox
- The Universal outside corner, Universal ledge trim and outlet covers in those same colors
Which do not
Harvest Ledge, Traditions, Summit Stone, Aged Brick and British Brick carry no fire rating claim, and neither do the faux beams and mantels or the caulking and touch-up kit. On a product page the badge follows the color you pick.
Need Class A in a color that isn't listed? Most of our range can be produced in a Class A version to order. There is an upcharge and a lead time - call or text 866-771-2345 and we will quote it.
Not fireproof. Tritan BP panels are not classified as non-combustible. Do not install them where fireproof or non-combustible materials are required, or where they would be exposed to open flame or direct heat.
ASTM E84 test reports are available from support@tritanbp.com, or call 866-771-2345.
Need the ASTM E84 test report for a building department, an architect or an insurer?
Request the full test reportWe send the report by email, usually the same business day.
Questions about a specific room or building?
Tell us where the panels are going and we will say plainly whether they are the right choice there.